Installation instructions and use
1. The interior of the main chassis security goalkeeper unscrew the cover screws to open the main chassis, open water there Suoyue
2. The main chassis with the left and right columns probe connector screw and nut in position angle iron is connected to the connection, tighten the nut.
3, the main chassis of aviation plug (big two) and the power plug and the left and right column of air outlet probe, connected to a power outlet. (Corresponding hole)
4, the infrared cable (two small) plug into the mainframe (infrared socket marked) in the corresponding socket.
5, the main chassis Replace the cover.
6, in the lower right side of the probe has a power outlet and switch, use 220V / AC, after turning on the power is turned on the power switch, security doors that enter the working state. Also waterproof security gate no power switch, power plug can be used directly.
Control Panel
Display Description:
1, the standby light (green square) for the power indicator light, power, green
Lit, security doors powered job.
2, when a metal object through the detection zone, signal lights flashing warning lights,
Horn sound an alarm, but the location lights, indicating the detected gold
In the case of goods which location. Digital display tube through the number displayed on the left and right
Alarm times.
The control panel debugging
Debugging Key Description
"Debug" button, commissioning of various data key
"Select" key, refer to the program key to select for each program
"OK" button to confirm the data after commissioning
"Reset" button, the number of statistics and alarm times return to zero; sensitivity after commissioning can confirm this key
Debugging method (step)
1, first press the reset button, press again. Press 2 to select key under the Enter key to see displayed. (d001)
2, and then press the "Select" button is displayed as "10 ××" ("1" represents the first location, "XX" representing the sensitivity value) into the zone digit debugging ("Debug" button debugging ten digits, "confirmed "button debugging digit); Example: Adjusting to the" 1085 "indicates the sensitivity of the first location is 85, can detect metal objects as a coin or small metal objects.
3, followed by "select" button, you can go to the next debugger, respectively, 2-7 location, its debug methods such as a same location. (The last area is the 7th district is to control the overall sensitivity.)
4. Keep pressing until after the 7th district, location sensitivity 1-7 after debugging, press the "Select" button (at this time is displayed as "d001"),
5. Finally, press the "Enter" key, then press the "reset" button, then stored at the
. D001 alarm in seconds debugging methods: (d001 meaning refers to: the length of time the number of alarms; this time for 1 second); 1, first press the reset button, press again. Press 2 to select key under the Enter key to see displayed. (d001) Press the "Start-up" adjustment generally choose one, then keep pressing the "Select" to the last show d001, then press "OK" and press the reset ';.. these days
First, the password settings:
Press the "Select" key and the display panel shows "1234", this number is the factory password
Second, press the "OK" button, then displayed as "0000"; (shown as "0000" indicates that the correct password, you can enter the next debugger; if displayed as "E000" is expressed as a wrong password security gate has been locked, you need to re-enter the correct password to unlock in order to debug)
Password change:
1, when the display panel shows as "E000", press "Select" key to enter numbers, press the "Start" key transposition input (8888, four 8 for universal password to unlock it.)
2. Press the "OK" button, press the "Select" key to enter numbers, press the "Start-up" transposition input (1234. factory password) and press "OK" and then "Reset" button. On it.